printer.py 25 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553
  1. from datetime import datetime
  2. from pydantic import BaseModel, Field, field_validator, model_validator
  3. from backend.app.schemas.not_null import IgnoresNullForRequiredColumns
  4. from backend.app.schemas.printer_location import normalize_location_name
  5. from backend.app.utils.printer_models import supports_nozzle_flow_type
  6. class PrinterBase(BaseModel):
  7. name: str = Field(..., min_length=1, max_length=100)
  8. serial_number: str = Field(..., min_length=1, max_length=50)
  9. @field_validator("serial_number")
  10. @classmethod
  11. def _normalize_serial_number(cls, v: str) -> str:
  12. """Uppercase and trim the serial number.
  13. Bambu serial numbers are uppercase alphanumeric, and the MQTT report
  14. topic ``device/<serial>/report`` is case-sensitive. A serial entered
  15. in the wrong case (or with stray whitespace) connects and subscribes
  16. without error but never receives a message — the printer publishes to
  17. the correctly-cased topic, so every status field stays unknown (#1465).
  18. Normalising on input makes the subscribed topic always match.
  19. """
  20. normalized = v.strip().upper()
  21. if not normalized:
  22. raise ValueError("serial_number must not be blank")
  23. return normalized
  24. ip_address: str = Field(
  25. ...,
  26. max_length=253,
  27. pattern=r"^(\d{1,3}(\.\d{1,3}){3}|[a-zA-Z0-9]([a-zA-Z0-9\-]{0,61}[a-zA-Z0-9])?(\.[a-zA-Z0-9]([a-zA-Z0-9\-]{0,61}[a-zA-Z0-9])?)*)$",
  28. )
  29. model: str | None = None
  30. location: str | None = None # Group/location name
  31. auto_archive: bool = True
  32. external_camera_url: str | None = None
  33. external_camera_type: str | None = None # "mjpeg", "rtsp", "snapshot", "usb"
  34. external_camera_enabled: bool = False
  35. external_camera_snapshot_url: str | None = None # Optional single-frame override; #1177
  36. camera_rotation: int = 0 # 0, 90, 180, 270 degrees
  37. camera_light_auto: bool = False # #1655, used when camera_light_mode is "selected"
  38. class PrinterCreate(PrinterBase):
  39. # access_code lives on the input shapes only — never on the default
  40. # PrinterResponse. Direct exposure on PRINTERS_READ would let a Viewer
  41. # connect to the printer's MQTT and bypass Bambuddy's RBAC.
  42. access_code: str = Field(..., min_length=1, max_length=20)
  43. # Input only, not on PrinterBase: SQLite never enforced the column width,
  44. # so a stored location may be longer, and the response must still read it.
  45. _location = field_validator("location")(normalize_location_name)
  46. class PlateDetectionROI(BaseModel):
  47. """Region of interest for plate detection (percentages 0.0-1.0)."""
  48. x: float = Field(..., ge=0.0, le=1.0) # X start %
  49. y: float = Field(..., ge=0.0, le=1.0) # Y start %
  50. w: float = Field(..., ge=0.0, le=1.0) # Width %
  51. h: float = Field(..., ge=0.0, le=1.0) # Height %
  52. class PrinterUpdate(IgnoresNullForRequiredColumns):
  53. __orm_table__ = "printers"
  54. name: str | None = None
  55. ip_address: str | None = Field(
  56. default=None,
  57. max_length=253,
  58. pattern=r"^(\d{1,3}(\.\d{1,3}){3}|[a-zA-Z0-9]([a-zA-Z0-9\-]{0,61}[a-zA-Z0-9])?(\.[a-zA-Z0-9]([a-zA-Z0-9\-]{0,61}[a-zA-Z0-9])?)*)$",
  59. )
  60. access_code: str | None = None
  61. model: str | None = None
  62. location: str | None = None
  63. _location = field_validator("location")(normalize_location_name)
  64. is_active: bool | None = None
  65. auto_archive: bool | None = None
  66. print_hours_offset: float | None = None
  67. # Wear cost per printing hour (#694); null or 0 turns it off.
  68. wear_cost_per_hour: float | None = Field(default=None, ge=0, le=100000)
  69. external_camera_url: str | None = None
  70. external_camera_type: str | None = None
  71. external_camera_enabled: bool | None = None
  72. external_camera_snapshot_url: str | None = None # #1177
  73. camera_rotation: int | None = None # 0, 90, 180, 270 degrees
  74. camera_light_auto: bool | None = None # #1655
  75. plate_detection_enabled: bool | None = None
  76. plate_detection_roi: PlateDetectionROI | None = None
  77. class PrinterResponse(PrinterBase):
  78. id: int
  79. is_active: bool
  80. nozzle_count: int = 1 # 1 or 2, auto-detected from MQTT
  81. # Whether the model is sold with both Standard and High Flow nozzles, so a
  82. # K-profile's flow type is a real choice rather than a meaningless field.
  83. # Derived from the model, not from nozzle_count — see
  84. # printer_models.supports_nozzle_flow_type.
  85. supports_nozzle_flow_type: bool = True
  86. print_hours_offset: float = 0.0
  87. wear_cost_per_hour: float | None = None # #694
  88. external_camera_url: str | None = None
  89. external_camera_type: str | None = None
  90. external_camera_enabled: bool = False
  91. external_camera_snapshot_url: str | None = None # #1177
  92. camera_rotation: int = 0 # 0, 90, 180, 270 degrees
  93. camera_light_auto: bool = False # #1655
  94. plate_detection_enabled: bool = False
  95. plate_detection_roi: PlateDetectionROI | None = None
  96. created_at: datetime
  97. updated_at: datetime
  98. class Config:
  99. from_attributes = True
  100. @classmethod
  101. def from_orm_with_roi(cls, printer) -> "PrinterResponse":
  102. """Create response from ORM model, converting ROI fields to nested object."""
  103. data = {
  104. "id": printer.id,
  105. "name": printer.name,
  106. "serial_number": printer.serial_number,
  107. "ip_address": printer.ip_address,
  108. "model": printer.model,
  109. "location": printer.location,
  110. "auto_archive": printer.auto_archive,
  111. "external_camera_url": printer.external_camera_url,
  112. "external_camera_type": printer.external_camera_type,
  113. "external_camera_enabled": printer.external_camera_enabled,
  114. "external_camera_snapshot_url": printer.external_camera_snapshot_url,
  115. "camera_rotation": printer.camera_rotation,
  116. "camera_light_auto": bool(printer.camera_light_auto),
  117. "is_active": printer.is_active,
  118. "nozzle_count": printer.nozzle_count,
  119. "supports_nozzle_flow_type": supports_nozzle_flow_type(printer.model),
  120. "print_hours_offset": printer.print_hours_offset,
  121. "wear_cost_per_hour": printer.wear_cost_per_hour,
  122. "plate_detection_enabled": printer.plate_detection_enabled,
  123. "created_at": printer.created_at,
  124. "updated_at": printer.updated_at,
  125. }
  126. # Build ROI object if any ROI field is set
  127. if any(
  128. [
  129. printer.plate_detection_roi_x is not None,
  130. printer.plate_detection_roi_y is not None,
  131. printer.plate_detection_roi_w is not None,
  132. printer.plate_detection_roi_h is not None,
  133. ]
  134. ):
  135. data["plate_detection_roi"] = PlateDetectionROI(
  136. x=printer.plate_detection_roi_x or 0.15,
  137. y=printer.plate_detection_roi_y or 0.35,
  138. w=printer.plate_detection_roi_w or 0.70,
  139. h=printer.plate_detection_roi_h or 0.55,
  140. )
  141. return cls(**data)
  142. class PrinterResponseWithSecret(PrinterResponse):
  143. """PrinterResponse + access_code. Returned ONLY to callers with
  144. PRINTERS_UPDATE (Admin / Operator JWTs, or single-trust auth-disabled mode).
  145. Viewers and API keys never receive this shape — they get the bare
  146. PrinterResponse without access_code, since holding the access_code lets
  147. the caller talk to the printer's MQTT directly and bypass Bambuddy's RBAC.
  148. """
  149. access_code: str
  150. class HMSErrorResponse(BaseModel):
  151. code: str
  152. attr: int = 0 # Attribute value for constructing wiki URL
  153. module: int
  154. severity: int # Bambu alert level: 1 error (stopped), 2 warning (paused), 3 notification, 0 invalid
  155. actions: list[str] = [] # List of user-facing action keys (e.g. "CHECK_FILAMENT")
  156. job_id: str | None = None # Optional job ID for actions that require it (e.g. "CHECK_ASSISTANT")
  157. # Canonical hex identifier the firmware uses to match HMS-related commands.
  158. # 16 chars for `hms[]`-array faults (full 64-bit attr+code), 8 chars for
  159. # `print_error` faults. The frontend echoes this back as
  160. # HmsActionBody.print_error so we send the firmware-recognised key, not the
  161. # truncated short_code that historically caused silent command rejection
  162. # (#1830, H2D wrong-plate verification).
  163. full_code: str = ""
  164. # The bundled catalogue's sentence for this fault, so a client does not have
  165. # to carry its own copy of the same table to tell a user why a print halted
  166. # (#2926). English only and not localized — the catalogue ships one language.
  167. # Generated from Bambu Studio's HMS files, keyed by `full_code` and the
  168. # printer model (#2728). None when Bambu publishes no text for the code,
  169. # which it does for some codes it lists. A client should treat null as "no
  170. # text available", never as "no fault" — `full_code` is what identifies the
  171. # fault, and it is always present.
  172. description: str | None = None
  173. def hms_error_responses(errors) -> list[HMSErrorResponse]:
  174. """A printer's live HMS faults (``PrinterState.hms_errors``) as API rows.
  175. Shared by the printer status route and the webhook status route, so a
  176. fault reads the same to the UI and to an API-key client (#2919).
  177. """
  178. return [
  179. HMSErrorResponse(
  180. code=e.code,
  181. attr=e.attr,
  182. module=e.module,
  183. severity=e.severity,
  184. actions=e.actions,
  185. job_id=e.job_id,
  186. full_code=e.full_code,
  187. description=e.description,
  188. )
  189. for e in (errors or [])
  190. ]
  191. class AMSTray(BaseModel):
  192. id: int
  193. tray_color: str | None = None
  194. tray_type: str | None = None
  195. tray_sub_brands: str | None = None # Full name like "PLA Basic", "PETG HF"
  196. tray_id_name: str | None = None # Bambu filament ID like "A00-Y2" (can decode to color)
  197. tray_info_idx: str | None = None # Filament preset ID like "GFA00"
  198. remain: int = 0
  199. k: float | None = None # Pressure advance value (from tray or K-profile lookup)
  200. cali_idx: int | None = None # Calibration index for K-profile lookup
  201. tag_uid: str | None = None # RFID tag UID (any tag)
  202. tray_uuid: str | None = None # Bambu Lab spool UUID (32-char hex)
  203. nozzle_temp_min: int | None = None # Min nozzle temperature
  204. nozzle_temp_max: int | None = None # Max nozzle temperature
  205. drying_temp: int | None = None # RFID-recommended drying temp
  206. drying_time: int | None = None # RFID-recommended drying time (hours)
  207. state: int | None = None # AMS tray state: 9=empty, 10=spool present not loaded, 11=loaded
  208. # Firmware's authoritative "spool physically present" bit (from tray_exist_bits).
  209. # True for a non-RFID spool the firmware can't identify — the UI shows "?" rather
  210. # than "Empty" (#2527). None when the bitmask was unavailable (→ state-based fallback).
  211. exists: bool | None = None
  212. class AMSUnit(BaseModel):
  213. id: int
  214. humidity: int | None = None
  215. temp: float | None = None
  216. is_ams_ht: bool = False # True for AMS-HT (single spool), False for regular AMS (4 spools)
  217. tray: list[AMSTray] = []
  218. serial_number: str = "" # AMS unit serial number (sn from MQTT)
  219. sw_ver: str = "" # AMS firmware version (from get_version info.module)
  220. dry_time: int = 0 # Minutes remaining (0 = not drying, >0 = drying active)
  221. # True when dry_time > 0 but the countdown has not ticked for over
  222. # DRY_COUNTDOWN_STALL_SECONDS with no active dry_status phase: the timer is
  223. # set but no cycle is running (never started, or paused partway).
  224. dry_countdown_stalled: bool = False
  225. dry_status: int = 0 # 0=Off, 1=Checking, 2=Drying, 3=Cooling, 4=Stopping, 5=Error
  226. dry_sub_status: int = 0 # 0=Off, 1=Heating, 2=Dehumidify
  227. dry_sf_reason: list[int] = [] # Cannot-dry reasons from firmware (see CannotDryReason)
  228. dry_target_temp: int | None = None # Active-cycle target °C (Bambu doesn't echo this)
  229. dry_filament: str | None = None # Active-cycle filament name we sent
  230. module_type: str = "" # "ams", "n3f", "n3s"
  231. class NozzleInfoResponse(BaseModel):
  232. nozzle_type: str = "" # "stainless_steel" or "hardened_steel"
  233. nozzle_diameter: str = "" # e.g., "0.4"
  234. class NozzleRackSlot(BaseModel):
  235. """H2C nozzle rack slot (6-position tool-changer dock)."""
  236. id: int = 0
  237. nozzle_type: str = ""
  238. nozzle_diameter: str = ""
  239. wear: int | None = None
  240. stat: int | None = None # Nozzle status (e.g. mounted/docked)
  241. max_temp: int = 0 # Max temperature rating °C (0 = not set)
  242. serial_number: str = "" # Nozzle serial number
  243. filament_color: str = "" # RGBA hex ("00000000" = no filament)
  244. filament_id: str = "" # Bambu filament ID
  245. filament_type: str = "" # Material type (e.g. "PLA", "PETG")
  246. class AmsLabelBody(BaseModel):
  247. label: str = Field(..., min_length=1, max_length=100)
  248. ams_serial: str = Field(default="", max_length=50)
  249. class HmsActionBody(BaseModel):
  250. # Canonical hex identifier (HMSErrorResponse.full_code): 8 chars for
  251. # `print_error`-sourced faults, 16 chars for `hms[]`-array faults whose
  252. # full 64-bit code is the firmware's matching key. Length-bounded to
  253. # those two valid shapes to keep stray input from reaching the dispatcher.
  254. print_error: str = Field(..., min_length=8, max_length=16, pattern=r"^[0-9A-Fa-f]{8}([0-9A-Fa-f]{8})?$")
  255. # One of the HMSAction enum values. Length-capped to keep stray input from
  256. # reaching the dispatcher's `match` statement.
  257. action: str = Field(..., min_length=1, max_length=64)
  258. # The `subtask_id` snapshot from the HMSError that surfaced this dialog.
  259. # Bambu echoes it back in HMS-aware commands. Optional for idle errors.
  260. job_id: str | None = Field(default=None, max_length=64)
  261. class FilaSwitchResponse(BaseModel):
  262. """Filament Track Switch (FTS) state — accessory that mediates AMS-to-extruder routing.
  263. When installed, the AMS info field reports bits 8-11 = 0xE (uninitialized)
  264. because slots are dynamically routed via the FTS rather than tied to a
  265. specific extruder. Frontend uses `installed` to suppress the per-extruder
  266. slot filter in the print modal. See #1162.
  267. """
  268. installed: bool = False
  269. # in[track] = currently loaded slot for that track (-1 = empty)
  270. in_slots: list[int] = []
  271. # out[track] = extruder this track terminates at (0 = right, 1 = left)
  272. out_extruders: list[int] = []
  273. stat: int = 0
  274. info: int = 0
  275. # Whether the switch is set up: every AMS bound to one of its two inlets.
  276. # A load cannot be routed until it is, so the UI blocks on this rather than
  277. # sending a command the firmware will drop.
  278. ready: bool = False
  279. class ExtruderSlotResponse(BaseModel):
  280. """Which AMS slot one hotend is currently fed from.
  281. From ``device.extruder.info[i].snow``. Needed because ``tray_now`` is a
  282. single printer-wide value: on a dual-nozzle machine with both hotends
  283. loaded it names only one of them, so it cannot say which hotend holds a
  284. given slot.
  285. """
  286. # None when the hotend is not fed from any slot.
  287. ams_id: int | None = None
  288. slot_id: int | None = None
  289. has_filament: bool = False
  290. class PrintOptionsResponse(BaseModel):
  291. """AI detection and print options from xcam data."""
  292. # Core AI detectors
  293. spaghetti_detector: bool = False
  294. print_halt: bool = False
  295. halt_print_sensitivity: str = "medium" # Spaghetti sensitivity
  296. first_layer_inspector: bool = False
  297. printing_monitor: bool = False
  298. buildplate_marker_detector: bool = False
  299. allow_skip_parts: bool = False
  300. # Additional AI detectors (decoded from cfg bitmask)
  301. nozzle_clumping_detector: bool = True
  302. nozzle_clumping_sensitivity: str = "medium"
  303. pileup_detector: bool = True
  304. pileup_sensitivity: str = "medium"
  305. airprint_detector: bool = True
  306. airprint_sensitivity: str = "medium"
  307. auto_recovery_step_loss: bool = True
  308. filament_tangle_detect: bool = False
  309. class PrinterStatus(BaseModel):
  310. id: int
  311. name: str
  312. connected: bool
  313. state: str | None = None
  314. current_print: str | None = None
  315. subtask_name: str | None = None
  316. gcode_file: str | None = None
  317. progress: float | None = None
  318. remaining_time: int | None = None
  319. layer_num: int | None = None
  320. total_layers: int | None = None
  321. temperatures: dict | None = None
  322. cover_url: str | None = None
  323. hms_errors: list[HMSErrorResponse] = []
  324. ams: list[AMSUnit] = []
  325. ams_exists: bool = False
  326. vt_tray: list[AMSTray] = [] # Virtual tray / external spool(s)
  327. sdcard: bool = False # SD card inserted
  328. store_to_sdcard: bool = False # Store sent files on SD card
  329. timelapse: bool = False # Timelapse recording active
  330. ipcam: bool = False # Live view enabled
  331. wifi_signal: int | None = None # WiFi signal strength in dBm
  332. wired_network: bool = False # Ethernet connection detected
  333. door_open: bool = False # Enclosure door open (X1/P1S/P2S/H2*)
  334. nozzles: list[NozzleInfoResponse] = [] # Nozzle hardware info (index 0=left/primary, 1=right)
  335. nozzle_rack: list[NozzleRackSlot] = [] # H2C 6-nozzle tool-changer rack
  336. print_options: PrintOptionsResponse | None = None # AI detection and print options
  337. # Calibration stage tracking
  338. stg_cur: int = -1 # Current stage number (-1 = not calibrating)
  339. stg_cur_name: str | None = None # Human-readable current stage name
  340. stg: list[int] = [] # List of stage numbers in calibration sequence
  341. # Air conditioning mode (0=cooling, 1=heating)
  342. airduct_mode: int = 0
  343. # Print speed level (1=silent, 2=standard, 3=sport, 4=ludicrous)
  344. speed_level: int = 2
  345. # Chamber light on/off
  346. chamber_light: bool = False
  347. # Active extruder for dual nozzle (0=right, 1=left)
  348. active_extruder: int = 0
  349. # AMS mapping for dual nozzle: which AMS is connected to which nozzle
  350. ams_mapping: list[int] = []
  351. # Per-AMS extruder map: {ams_id: extruder_id} where 0=right, 1=left
  352. ams_extruder_map: dict[str, int] = {}
  353. # Filament Track Switch (FTS) accessory — when installed, AMS reports
  354. # bits 8-11 = 0xE (uninitialized) and routing is dynamic via the FTS. See #1162.
  355. fila_switch: FilaSwitchResponse | None = None
  356. # Per-AMS FTS inlet binding: {ams_id: "A" | "B"}, from AMS info bits 24-27.
  357. # Which of the switch's two inlets each AMS is plumbed into, as set on the
  358. # printer's "Manual AMS Setup" screen. Empty unless an FTS is installed —
  359. # an FTS-bound AMS reaches BOTH nozzles, so it has no entry in
  360. # ams_extruder_map and must not be labelled left or right.
  361. ams_switch_inlet: dict[str, str] = {}
  362. # Which AMS slot each hotend is fed from, keyed by extruder id as a string
  363. # ("0" = right/main, "1" = left/deputy). Empty on printers that do not
  364. # report ``device.extruder.info``.
  365. extruder_slots: dict[str, ExtruderSlotResponse] = {}
  366. # Currently loaded tray (global ID): 254 = external spool, 255 = no filament
  367. tray_now: int = 255
  368. # The trays this print has drawn from, in order: [[global tray ID, layer the
  369. # switch happened at], ...]. A tray outside the job's AMS mapping is a backup
  370. # spool the printer switched to (AMS Filament Backup); the queue card shows it
  371. # in place of the slot that ran out. Reset at the start of each print.
  372. tray_change_log: list[list[int]] = []
  373. # Runout / filament-replacement guidance (#2587). Populated only while the
  374. # print is PAUSED. Both are globalised tray IDs (ams_id*4+slot, or 128-135 for
  375. # AMS-HT, or 254 for external) so the frontend can highlight them with the same
  376. # logic it uses for tray_now:
  377. # expected_tray = the slot the firmware now expects filament in (from tray_tar).
  378. # None when idle, not paused, or the slot can't be resolved
  379. # (multi-AMS ambiguity) — the UI then says "check the printer".
  380. # previous_tray = the slot loaded before the pause, i.e. the one that ran out
  381. # (from tray_pre). None when unknown.
  382. expected_tray: int | None = None
  383. previous_tray: int | None = None
  384. # AMS status for filament change tracking
  385. # Main status: 0=idle, 1=filament_change, 2=rfid_identifying, 3=assist, 4=calibration
  386. ams_status_main: int = 0
  387. # Sub status: specific step within filament change (when main=1)
  388. # Known values: 4=retraction, 6=load verification, 7=purge
  389. ams_status_sub: int = 0
  390. # mc_print_sub_stage - filament change step indicator used by OrcaSlicer/BambuStudio
  391. mc_print_sub_stage: int = 0
  392. # Timestamp of last AMS data update (for RFID refresh detection)
  393. last_ams_update: float = 0.0
  394. # Number of printable objects in current print (for skip objects feature)
  395. printable_objects_count: int = 0
  396. # Fan speeds (0-100 percentage, None if not available for this model)
  397. cooling_fan_speed: int | None = None # Part cooling fan
  398. big_fan1_speed: int | None = None # Auxiliary fan
  399. big_fan2_speed: int | None = None # Chamber/exhaust fan
  400. heatbreak_fan_speed: int | None = None # Hotend heatbreak fan
  401. # Left auxiliary part cooling fan (optional P2S/X2D accessory, airduct part id 10).
  402. # None = not installed / not reported by this model.
  403. left_aux_fan_speed: int | None = None
  404. # Chamber exhaust fan present (P2S/X2D External Exhaust Fan kit; airduct part id 3).
  405. exhaust_fan_present: bool = False
  406. # Firmware version (from info.module[name="ota"].sw_ver)
  407. firmware_version: str | None = None
  408. # Developer LAN mode: True = enabled, False = disabled (MQTT encryption), None = unknown
  409. developer_mode: bool | None = None
  410. # AMS Filament Backup ("auto-switch" to a second spool when one runs out).
  411. # True = ON, False = OFF, None = unknown / unsupported (A1 family — protocol field
  412. # not yet identified). UI treats None as "status unavailable", not as a hard disable.
  413. ams_filament_backup: bool | None = None
  414. # Queue: printer is awaiting the user to acknowledge the build plate is cleared
  415. # after a finished/failed print. Persisted across restarts (#961).
  416. awaiting_plate_clear: bool = False
  417. # AMS drying support
  418. supports_drying: bool = False
  419. # AMS "Print While Drying" — drying mid-print. Verified per Bambu wiki release notes;
  420. # see _DRY_WHILE_PRINTING_MIN_FIRMWARE in printer_manager.py for the matrix.
  421. supports_drying_while_printing: bool = False
  422. # The AMS can dry, but only from the printer's own screen (P1 series, #2533).
  423. # supports_drying is False on these; the UI keeps the control visible but disabled
  424. # and says why, rather than dropping it without explanation.
  425. drying_screen_only: bool = False
  426. # Active chamber heater (responds to M141). True only for H2C/H2D/H2DPro/H2S/X2D.
  427. supports_chamber_heater: bool = False
  428. # Linked archive for the active print (resolved via subtask_id). Frontend uses
  429. # this to fetch plate metadata and show the plate name when the source 3MF is
  430. # multi-plate (#881 follow-up).
  431. current_archive_id: int | None = None
  432. # 1-indexed plate number parsed from gcode_file (e.g. /Metadata/plate_2.gcode).
  433. # Set for every active print regardless of plate count; the frontend decides
  434. # whether to render it based on current_archive_id's is_multi_plate flag.
  435. current_plate_id: int | None = None
  436. class DiagnosticCheck(BaseModel):
  437. """One connection-diagnostic check result.
  438. ``id`` is a stable key (port_mqtt, port_ftps, port_rtsps,
  439. macos_local_network, network_mode, subnet, external_storage, mqtt_auth,
  440. developer_mode, printer_publishing); the frontend renders the localized
  441. title and fix text from id + status. ``params`` carries interpolation
  442. values (e.g. network mode, IP addresses) for that text.
  443. Not every check is emitted on every run: ``macos_local_network`` appears
  444. only on macOS, where it is the only platform it can say anything about.
  445. """
  446. id: str
  447. status: str # "pass" | "fail" | "warn" | "skip"
  448. params: dict = Field(default_factory=dict)
  449. class PrinterDiagnosticResult(BaseModel):
  450. """Result of a printer connection diagnostic run."""
  451. printer_id: int | None = None
  452. ip_address: str
  453. overall: str # "ok" | "warnings" | "problems"
  454. checks: list[DiagnosticCheck]
  455. class DiagnosticRequest(BaseModel):
  456. """Pre-save (Add Printer) connection diagnostic request.
  457. serial_number + access_code are optional: when both are present the
  458. diagnostic also probes MQTT credentials, otherwise only the
  459. network-level checks run.
  460. """
  461. ip_address: str
  462. serial_number: str | None = None
  463. access_code: str | None = None
  464. class PrinterFilesDownloadRequest(BaseModel):
  465. """Printer paths selected for a bulk download."""
  466. paths: list[str] = Field(..., max_length=1000)
  467. sizes: dict[str, int] = Field(default_factory=dict, max_length=1000)
  468. @model_validator(mode="after")
  469. def _validate_sizes(self):
  470. """Validate optional FTP-reported sizes used for early rejection."""
  471. if self.sizes and set(self.sizes) != set(self.paths):
  472. raise ValueError("A size is required for every selected printer path")
  473. if any(size < 0 for size in self.sizes.values()):
  474. raise ValueError("Printer file sizes must not be negative")
  475. return self
  476. class PrinterFilesJobRequest(PrinterFilesDownloadRequest):
  477. """Browser preparation request, including native download presentation."""
  478. filename: str = Field(default="printer-files.zip", min_length=1, max_length=255)
  479. as_zip: bool = True