hms_catalog_extra.json 3.1 KB

1234567891011121314151617181920212223242526272829
  1. {
  2. "_comment": "print_error texts Bambu Studio does not ship, kept from the ha-bambulab table Bambuddy used before #2728. scripts/generate_hms_catalog.py adds them only where Studio has no entry. Keys are the 8-hex print_error value.",
  3. "error": {
  4. "03008002": "First layer defects were detected by the Micro Lidar. Please check the quality of the printed model before continuing your print.",
  5. "03008004": "Filament ran out. Please load new filament.",
  6. "03008006": "The build plate marker was not detected. Please confirm the build plate is correctly positioned on the heatbed with all four corners aligned, and the marker is visible.",
  7. "03008011": "Detected build plate is not the same as the Gcode file. Please adjust slicer settings or use the correct plate.",
  8. "0300801B": "Nozzle temperature problem detected. Refer to Assistant to re-connect the hotend connector. POWER OFF the printer before this operation to avoid short circuits.",
  9. "03008057": "The rotary attachment is disconnected. Please ensure it is properly installed and the cable is securely plugged in.",
  10. "03008058": "The rotary attachment is detected. Please remove it before continuing.",
  11. "050040A3": "AMS(or AMS lite) A communication is abnormal. Please reconnect the module cable or restart the printer.",
  12. "050040A4": "The current firmware only supports 1 AMS Lite. Please remove all AMS units before reconnecting the supported AMS Lite device.",
  13. "050040A5": "The current firmware only supports AMS/AMS 2 Pro/AMS HT, with a maximum of 4 units. Please remove all AMS units before reconnecting the supported one.",
  14. "05008048": "The module on the toolhead is not calibrated. Please cancel the task to perform calibration or switch to a calibrated module.",
  15. "050140A3": "AMS(or AMS lite) B communication is abnormal. Please reconnect the module cable or restart the printer.",
  16. "050240A3": "AMS(or AMS lite) C communication is abnormal. Please reconnect the module cable or restart the printer.",
  17. "050340A3": "AMS(or AMS lite) D communication is abnormal. Please reconnect the module cable or restart the printer.",
  18. "058040A2": "AMS-HT A communication is abnormal. Please reconnect the module cable or restart the printer.",
  19. "058140A2": "AMS-HT B communication is abnormal. Please reconnect the module cable or restart the printer.",
  20. "058240A2": "AMS-HT C communication is abnormal. Please reconnect the module cable or restart the printer.",
  21. "058340A2": "AMS-HT D communication is abnormal. Please reconnect the module cable or restart the printer.",
  22. "058440A2": "AMS-HT E communication is abnormal. Please reconnect the module cable or restart the printer.",
  23. "058540A2": "AMS-HT F communication is abnormal. Please reconnect the module cable or restart the printer.",
  24. "058640A2": "AMS-HT G communication is abnormal. Please reconnect the module cable or restart the printer.",
  25. "058740A2": "AMS-HT H communication is abnormal. Please reconnect the module cable or restart the printer.",
  26. "0C008001": "First layer defects were detected. If the defects are acceptable, select 'Resume' to resume the print job.",
  27. "0C00C003": "Possible defects were detected in the first layer."
  28. }
  29. }