maziggy
|
ee2d6e69aa
test: close the coroutines that mocked create_task, wait_for, run_coroutine_threadsafe, spawn_background_task and AsyncMock sessions left unawaited (reported as unraisable warnings in unrelated later tests); the Spoolman recovery tests archive under their own tmp_path instead of the shared archive/
|
1 päivä sitten |
maziggy
|
460c11ca30
chore: remove dead code (audit step 4): unused backend helpers and schema classes, 51 unused API client wrappers, test-only components (BackupModal, RestoreModal, VirtualPrinterSettings, TagDetectedModal, WeightDisplay, useLongPress) and their translations; removed POST /printers/test, the two printer debug routes and the SpoolBuddy update-status channel; legacy virtual printer settings fields removed from the settings API; first-run setup redirect tested
|
1 päivä sitten |
maziggy
|
26e9a05707
fix(queue): a plate printed from the external spool keeps the AMS off on multi-plate files; slot reuse respects the finish; any-model VPs keep the AMS on; cloud filament id read from the preset too
|
4 päivää sitten |
maziggy
|
cacaaf4dae
fix(printers): live status carries nozzles, firmware, developer mode and the print's AMS mapping; run-out hint narrows by nozzle; AMS-HT is its unit id; rotate check sees loaded slots
|
4 päivää sitten |
maziggy
|
2bceb1f6b4
Show the backup spool on a printing queue job's card once AMS Filament Backup takes over
|
2 viikkoa sitten |
maziggy
|
3e646febd6
Don't log a printer callback cancelled at shutdown as an error (#3243)
|
2 viikkoa sitten |
M2ABRAMSTANK
|
6c0292b09a
fix(ams): show a parked drying command as not started instead of an active cycle (#3096)
|
3 viikkoa sitten |
maziggy
|
2c7c97c130
fix(jog): send the nozzle-bed gap the API promises on every model (issue #1334)
|
1 kuukausi sitten |
maziggy
|
9500c046c0
Ask which nozzle to feed when a Filament Track Switch is fitted
|
1 kuukausi sitten |
maziggy
|
7a42e0a7e5
Show which Filament Track Switch inlet each AMS feeds
|
2 kuukautta sitten |
maziggy
|
ec26cba927
Resolve the H2C rack nozzle at dispatch instead of letting firmware pick (#2800)
|
2 kuukautta sitten |
maziggy
|
fce7ea0200
Stop the drying badge inventing a temperature on a uniform AMS (#2759)
|
2 kuukautta sitten |
maziggy
|
33ab5f1ead
Add temperatures to the streaming overlay and a URL builder (#1422)
|
2 kuukautta sitten |
maziggy
|
48c231d8ce
Stop a drying cycle reporting itself finished a minute in (#2759)
|
2 kuukautta sitten |
maziggy
|
13183e365a
fix(ams): clear empty AMS-HT slot via its real tray_exist_bits position (#2670)
|
2 kuukautta sitten |
maziggy
|
56accd24de
fix(smart-plugs): don't blank printer state when an accessory plug switches off (#2629)
|
3 kuukautta sitten |
maziggy
|
2e45893dd5
feat(print-options): add "Auto" state to bed levelling, flow & nozzle-offset calibration
|
3 kuukautta sitten |
maziggy
|
b8cd1ab22d
fix(cover): release the DB connection before the FTP thumbnail download (#2572)
|
3 kuukautta sitten |
maziggy
|
ca3f6e5ee0
fix(drying): P1 AMS drying is screen-only — stop offering it (#2533)
|
3 kuukautta sitten |
maziggy
|
d568307eac
fix(smart-plug): don't cut power when a print restarts, honor per-plug cooldown setting (#1890)
|
3 kuukautta sitten |
maziggy
|
fd61812d01
feat(drying): show active-cycle filament + target temperature on the AMS drying badge
|
3 kuukautta sitten |
maziggy
|
8d6f701f1d
feat(drying): continue drying while printing + gate rotate-spool when tray loaded (issue #1816)
|
3 kuukautta sitten |
maziggy
|
166e9f9ef2
fix(vp): correct #1780 root cause — VP intake key mismatch dropped every slicer field
|
4 kuukautta sitten |
maziggy
|
d196cfc500
fix(virtual-printer): forward H2C rack-swap nozzle pick from slicer to dispatch (#1780)
|
4 kuukautta sitten |
maziggy
|
2c2725cb53
fix(print): expose nozzle_offset_cali toggle for dual-nozzle printers (#1682)
|
4 kuukautta sitten |
maziggy
|
51abc4b7a8
feat(drying): enable AMS drying for H2C at firmware 01.02.00.00+ (issue #1624)
|
4 kuukautta sitten |
maziggy
|
0406487eb3
Fix: Add Printer no longer hangs the container on P1S (#1445)
|
5 kuukautta sitten |
maziggy
|
7d3af9834c
fix(inventory): emulate state=9 for bare-tray empty-slot signal on P1S/A1 (#1322)
|
5 kuukautta sitten |
maziggy
|
a2c9eef87c
fix(safety): invert bed-jog Z direction on A1 / A1 Mini bed-slingers (#1334)
|
5 kuukautta sitten |
maziggy
|
889c8bd87f
fix(printers): show correct plate thumbnail on multi-plate 3MFs (#1166)
|
5 kuukautta sitten |