maziggy
|
460c11ca30
chore: remove dead code (audit step 4): unused backend helpers and schema classes, 51 unused API client wrappers, test-only components (BackupModal, RestoreModal, VirtualPrinterSettings, TagDetectedModal, WeightDisplay, useLongPress) and their translations; removed POST /printers/test, the two printer debug routes and the SpoolBuddy update-status channel; legacy virtual printer settings fields removed from the settings API; first-run setup redirect tested
|
1 روز پیش |
maziggy
|
ac4806f029
fix: a failed first run no longer leaves the archive at its partial cost (built-in inventory); completion stops the start cost estimate before writing the real cost; 2FA/SSO logins report LDAP/OIDC users' auth source; a fault in both print_error and HMS is listed once; a refused H2D load's tray target expires; refused K-profile re-applies are logged; the cloud filament-name map is fetched once per account without holding a DB connection; the library edit route refuses folder changes across the external boundary; a slow slice-progress answer is not reported as an unreachable sidecar
|
2 روز پیش |
maziggy
|
2b5cd87c7f
fix(queue): pipeline cancel stops the preheat and frees the budget; an offline stop frees the budget; the SD cleanup at a print's end is bounded to 45 s; a refused print start is logged and retried at once without a reconnect
|
3 روز پیش |
maziggy
|
e05a917445
fix(notifications,drying): printer-limited channels get only their printer's events; blocking mode pre-dries for scheduled jobs; model jobs say "(drying)"; remove dead load-tray state
|
4 روز پیش |
maziggy
|
e3824097fa
fix(mqtt): an H2D's active slot is read against the same message's nozzle data, and older nozzle data no longer overrules it
|
4 روز پیش |
maziggy
|
26e9a05707
fix(queue): a plate printed from the external spool keeps the AMS off on multi-plate files; slot reuse respects the finish; any-model VPs keep the AMS on; cloud filament id read from the preset too
|
4 روز پیش |
maziggy
|
f45cc599f3
fix(kprofiles): an AMS change leaves the K-profile to the lost-selection check; command answers no longer change the nozzle; unconfirmed writes say so and edits read back; skip refusals are logged; stop-drying toast says sent
|
4 روز پیش |
maziggy
|
cacaaf4dae
fix(printers): live status carries nozzles, firmware, developer mode and the print's AMS mapping; run-out hint narrows by nozzle; AMS-HT is its unit id; rotate check sees loaded slots
|
4 روز پیش |
maziggy
|
5a9415e2e1
fix(ams): Load and Unload work on an AMS-HT
|
4 روز پیش |
maziggy
|
be0ad787b4
fix(a2l): AMS Lite trays in captured and slicer mappings keep their global id
|
5 روز پیش |
maziggy
|
b5cd369f51
chore: remove dead code and fail CI on unused frontend files
|
1 هفته پیش |
simplytoast1
|
b42d39ffcc
Add native Notify! alerts, Live Activities and Lock Screen widgets (#3265)
|
1 هفته پیش |
maziggy
|
d9759be90c
Follow AMS Filament Backup toggles without a Force Refresh on printers without cfg (#3259)
|
1 هفته پیش |
maziggy
|
170335e8dc
Log home_flag changes on printers without cfg to check AMS Filament Backup in update frames (#3259)
|
2 هفته پیش |
maziggy
|
e7dd899963
Read AMS Filament Backup from home_flag on printers without cfg (#3259)
|
2 هفته پیش |
maziggy
|
84f320b859
Remember when each spool was last dried (#2863)
|
2 هفته پیش |
maziggy
|
3ddd324f87
Keep the loaded tray while an H2 slot is ambiguous (#3242)
|
2 هفته پیش |
maziggy
|
1cc4bae5d2
Report a refused RFID refresh, and fall back to M620 R (#3206)
|
3 هفته پیش |
maziggy
|
033eff1254
Show Bambu's own HMS descriptions and the real alert level (issue #2728)
|
3 هفته پیش |
M2ABRAMSTANK
|
6c0292b09a
fix(ams): show a parked drying command as not started instead of an active cycle (#3096)
|
3 هفته پیش |
maziggy
|
37502719b7
Fix external-spool usage charged to an AMS spool (#3166)
|
3 هفته پیش |
maziggy
|
6e8d543d2a
fix(ams): stop showing the humidity drop index as a percentage (issue #3140)
|
4 هفته پیش |
maziggy
|
8e9821dd2a
fix(mqtt): never wait for a wedged paho network thread (issue #3068)
|
1 ماه پیش |
maziggy
|
0b830ac35c
fix(ams): stop reading the printer's command acks as status (issue #3040)
|
1 ماه پیش |
maziggy
|
0d21239e18
Send AMS tray colours as uppercase hex (issue #2987)
|
1 ماه پیش |
maziggy
|
a7b563334e
Configure a spool's filament preset and K profile per nozzle
|
1 ماه پیش |
maziggy
|
9500c046c0
Ask which nozzle to feed when a Filament Track Switch is fitted
|
1 ماه پیش |
maziggy
|
14f46510ba
File the printer's calibration table under the nozzle it belongs to (issue #2854)
|
1 ماه پیش |
maziggy
|
935d4b5bbf
Charge the tray the printer said it used, not the first one loaded (issue #2953)
|
1 ماه پیش |
maziggy
|
5dd7bd213f
Read a print's destination from the report topic, not just the request one (issue #1820)
|
1 ماه پیش |