@@ -0,0 +1,56 @@
|
|
|
+/**
|
|
|
+ * Regression test for the PA-Profil picker's nozzle blindness (#2618).
|
|
|
+ *
|
|
|
+ * When a printer has two K-profiles for the same filament that differ only in
|
|
|
+ * nozzle size (e.g. PAHT-CF at 0.4mm K=0.042 and 0.6mm K=0.028), the picker
|
|
|
+ * must offer BOTH and label each with its nozzle diameter — not collapse to a
|
|
|
+ * single entry. The underlying cause lived in the fetch (it defaulted to the
|
|
|
+ * 0.4mm nozzle and never retrieved the 0.6mm profile); this test guards the
|
|
|
+ * rendering half: given both calibrations, the section shows both with a
|
|
|
+ * nozzle badge so they are distinguishable.
|
|
|
+ */
|
|
|
+
|
|
|
+import { describe, it, expect, vi } from 'vitest';
|
|
|
+import { render, screen } from '@testing-library/react';
|
|
|
+import { I18nextProvider } from 'react-i18next';
|
|
|
+import i18n from '../../../i18n';
|
|
|
+import { PAProfileSection } from '../../../components/spool-form/PAProfileSection';
|
|
|
+import { defaultFormData } from '../../../components/spool-form/types';
|
|
|
+import type { PrinterWithCalibrations } from '../../../components/spool-form/types';
|
|
|
+
|
|
|
+const printers = [
|
|
|
+ {
|
|
|
+ printer: { id: 1, name: 'H2D', connected: true },
|
|
|
+ calibrations: [
|
|
|
+ // Same filament (non-generic id → id-match), different nozzle + extruder.
|
|
|
+ { cali_idx: 10, filament_id: 'GFN05', setting_id: '', name: 'PAHT-CF', k_value: 0.042, n_coef: 0, extruder_id: 0, nozzle_diameter: '0.4' },
|
|
|
+ { cali_idx: 11, filament_id: 'GFN05', setting_id: '', name: 'PAHT-CF', k_value: 0.028, n_coef: 0, extruder_id: 1, nozzle_diameter: '0.6' },
|
|
|
+ ],
|
|
|
+ },
|
|
|
+] as unknown as PrinterWithCalibrations[];
|
|
|
+
|
|
|
+describe('PAProfileSection nozzle-specific profiles (#2618)', () => {
|
|
|
+ it('renders both nozzle profiles for one filament, each with a nozzle badge', () => {
|
|
|
+ render(
|
|
|
+ <I18nextProvider i18n={i18n}>
|
|
|
+ <PAProfileSection
|
|
|
+ formData={{ ...defaultFormData, material: 'PAHT-CF', slicer_filament: 'GFN05' }}
|
|
|
+ updateField={vi.fn()}
|
|
|
+ printersWithCalibrations={printers}
|
|
|
+ selectedProfiles={new Set()}
|
|
|
+ setSelectedProfiles={vi.fn()}
|
|
|
+ expandedPrinters={new Set(['1'])}
|
|
|
+ setExpandedPrinters={vi.fn()}
|
|
|
+ />
|
|
|
+ </I18nextProvider>,
|
|
|
+ );
|
|
|
+
|
|
|
+ // Both nozzle-specific K values are offered — not just the 0.4mm one.
|
|
|
+ expect(screen.getByText('K=0.042')).toBeInTheDocument();
|
|
|
+ expect(screen.getByText('K=0.028')).toBeInTheDocument();
|
|
|
+
|
|
|
+ // Each is labelled by its nozzle so identically-named profiles are distinct.
|
|
|
+ expect(screen.getByText('0.4mm')).toBeInTheDocument();
|
|
|
+ expect(screen.getByText('0.6mm')).toBeInTheDocument();
|
|
|
+ });
|
|
|
+});
|