- **A camera window no longer opens a dozen streams to the printer at once (#3431, reported by @buffdriver)** — When the floating camera window was open while the page loaded (after a refresh, for example), Bambuddy opened about twenty camera streams for it. Only one was shown. The browser kept the rest open until the tab was closed, and they filled its six connections to the server. The page started each stream while still preparing to draw the window. It prepared the window several times before showing it, and every attempt left a stream behind. Streams now start only once the window is on the page. The camera page, the camera wall and the stream overlay start their streams the same way.
|
|
|
- **A printer whose file service hangs during a print is no longer asked again and again until it refuses every upload (#3474, reported by @F9mm)** — When the card could not be read at print start, the timelapse baseline was read again every two minutes for the whole print, and each round walked the card twice: up to eight new FTPS connections, each hanging for 30 s against a hung printer. An H2S kept a session for every one of them, then answered every connection with "421 There are too many connections", and no queued job could reach it until the printer was restarted. The card is now read once per round. It is read again only while the print records a timelapse, the wait doubles after each failed round (up to 30 minutes), and it stops after five. A connection or listing that times out now pauses the background timelapse scans of that printer for five minutes. Opening files and sending prints are not held up by this. A printer that answers "421 too many connections" now gets its own message in the queue, saying it may need a restart, instead of "Bambuddy will retry automatically". Wiki updated.
|