@@ -0,0 +1,233 @@
|
|
|
+"""Auto-drying and a countdown the firmware never runs (#3478).
|
|
|
+
|
|
|
+An AMS HT took a drying command mid-print and left the heater off: dry_time
|
|
|
+sat at 720 with dry_status Off for a week. The MQTT layer flags that as
|
|
|
+dry_countdown_stalled, but auto-drying treated any dry_time > 0 as a running
|
|
|
+cycle, so the unit was never dried again. Now a parked timer is not drying: a
|
|
|
+cycle Bambuddy armed that parks is closed out and counted on its own (it says
|
|
|
+nothing about humidity), and two in a row suspend the unit with a message that
|
|
|
+says the printer did not heat.
|
|
|
+"""
|
|
|
+
|
|
|
+import time
|
|
|
+from unittest.mock import AsyncMock, MagicMock, patch
|
|
|
+
|
|
|
+import pytest
|
|
|
+
|
|
|
+from backend.app.services.print_scheduler import (
|
|
|
+ AUTO_DRY_MAX_NEVER_HEATED_CYCLES,
|
|
|
+ AUTO_DRY_REARM_COOLDOWN_SECONDS,
|
|
|
+ PrintScheduler,
|
|
|
+)
|
|
|
+
|
|
|
+UNIT = (1, 128)
|
|
|
+WET = 75
|
|
|
+DRY = 50
|
|
|
+
|
|
|
+
|
|
|
+def _state(dry_time: int, stalled: bool, humidity: int = WET):
|
|
|
+ state = MagicMock()
|
|
|
+ state.raw_data = {
|
|
|
+ "ams": [
|
|
|
+ {
|
|
|
+ "id": 128,
|
|
|
+ "module_type": "n3s",
|
|
|
+ "dry_time": dry_time,
|
|
|
+ "dry_status": 0,
|
|
|
+ "dry_countdown_stalled": stalled,
|
|
|
+ "humidity_raw": str(humidity),
|
|
|
+ "dry_sf_reason": [],
|
|
|
+ "tray": [{"tray_type": "PLA"}],
|
|
|
+ }
|
|
|
+ ]
|
|
|
+ }
|
|
|
+ state.firmware_version = "01.09.00.00"
|
|
|
+ return state
|
|
|
+
|
|
|
+
|
|
|
+def _setting(value):
|
|
|
+ s = MagicMock()
|
|
|
+ s.value = value
|
|
|
+ return s
|
|
|
+
|
|
|
+
|
|
|
+def _db():
|
|
|
+ settings = {
|
|
|
+ "queue_drying_enabled": _setting("false"),
|
|
|
+ "ambient_drying_enabled": _setting("true"),
|
|
|
+ "ams_humidity_fair": _setting("60"),
|
|
|
+ "queue_drying_block": _setting("false"),
|
|
|
+ }
|
|
|
+
|
|
|
+ async def execute(stmt):
|
|
|
+ result = MagicMock()
|
|
|
+ try:
|
|
|
+ params = list(stmt.compile().params.values())
|
|
|
+ except Exception:
|
|
|
+ params = []
|
|
|
+ for key, val in settings.items():
|
|
|
+ if key in params:
|
|
|
+ result.scalar_one_or_none.return_value = val
|
|
|
+ return result
|
|
|
+ if "printer" in str(stmt).lower():
|
|
|
+ printer = MagicMock()
|
|
|
+ printer.id = 1
|
|
|
+ printer.is_active = True
|
|
|
+ scalars = MagicMock()
|
|
|
+ scalars.__iter__ = MagicMock(return_value=iter([printer]))
|
|
|
+ result.scalars.return_value = scalars
|
|
|
+ else:
|
|
|
+ result.scalar_one_or_none.return_value = None
|
|
|
+ return result
|
|
|
+
|
|
|
+ db = AsyncMock()
|
|
|
+ db.execute = AsyncMock(side_effect=execute)
|
|
|
+ return db
|
|
|
+
|
|
|
+
|
|
|
+@pytest.fixture
|
|
|
+def env():
|
|
|
+ with (
|
|
|
+ patch("backend.app.services.print_scheduler.printer_manager") as pm,
|
|
|
+ patch("backend.app.services.print_scheduler.notification_service") as notify,
|
|
|
+ patch("backend.app.services.print_scheduler.supports_drying", return_value=True),
|
|
|
+ ):
|
|
|
+ pm.is_connected.return_value = True
|
|
|
+ pm.get_model.return_value = "P2S"
|
|
|
+ pm.send_drying_command.return_value = True
|
|
|
+ notify.on_ams_drying_suspended = AsyncMock()
|
|
|
+ scheduler = PrintScheduler()
|
|
|
+ scheduler._is_printer_idle = MagicMock(return_value=True)
|
|
|
+ db = _db()
|
|
|
+
|
|
|
+ async def run(dry_time, stalled, humidity=WET):
|
|
|
+ pm.get_status.return_value = _state(dry_time, stalled, humidity)
|
|
|
+ await scheduler._check_auto_drying(db, [], set())
|
|
|
+
|
|
|
+ yield scheduler, pm, notify, run
|
|
|
+
|
|
|
+
|
|
|
+def _age_out_cooldown(scheduler):
|
|
|
+ scheduler._auto_dry_units[UNIT]["ended_at"] -= AUTO_DRY_REARM_COOLDOWN_SECONDS + 1
|
|
|
+
|
|
|
+
|
|
|
+async def _parked_cycle(run):
|
|
|
+ """Arm, see the command taken, then see the stall detector flag it."""
|
|
|
+ await run(0, False)
|
|
|
+ await run(720, False)
|
|
|
+ await run(720, True)
|
|
|
+
|
|
|
+
|
|
|
+class TestParkedTimerIsNotDrying:
|
|
|
+ @pytest.mark.asyncio
|
|
|
+ async def test_a_parked_timer_bambuddy_did_not_start_gets_a_start(self, env):
|
|
|
+ """The reporter's unit: parked at 720, humidity above the threshold."""
|
|
|
+ scheduler, pm, _notify, run = env
|
|
|
+ await run(720, True)
|
|
|
+ pm.send_drying_command.assert_called_once_with(1, 128, 45, 12, mode=1, filament="PLA")
|
|
|
+ assert scheduler._auto_dry_units[UNIT]["running"] is True
|
|
|
+
|
|
|
+ @pytest.mark.asyncio
|
|
|
+ async def test_a_timer_not_yet_called_parked_still_runs(self, env):
|
|
|
+ _scheduler, pm, _notify, run = env
|
|
|
+ await run(720, False)
|
|
|
+ pm.send_drying_command.assert_not_called()
|
|
|
+
|
|
|
+ @pytest.mark.asyncio
|
|
|
+ async def test_a_parked_cycle_is_closed_counted_apart_and_cools_off(self, env):
|
|
|
+ scheduler, pm, _notify, run = env
|
|
|
+ await _parked_cycle(run)
|
|
|
+
|
|
|
+ unit = scheduler._auto_dry_units[UNIT]
|
|
|
+ assert "running" not in unit
|
|
|
+ assert unit["never_heated"] == 1
|
|
|
+ assert unit.get("unproductive", 0) == 0
|
|
|
+ assert "best_end_humidity" not in unit
|
|
|
+ assert isinstance(unit["ended_at"], float)
|
|
|
+
|
|
|
+ await run(720, True)
|
|
|
+ assert pm.send_drying_command.call_count == 1
|
|
|
+
|
|
|
+ @pytest.mark.asyncio
|
|
|
+ async def test_parked_cycles_suspend_with_the_not_heating_message(self, env):
|
|
|
+ scheduler, pm, notify, run = env
|
|
|
+ for _ in range(AUTO_DRY_MAX_NEVER_HEATED_CYCLES - 1):
|
|
|
+ await _parked_cycle(run)
|
|
|
+ _age_out_cooldown(scheduler)
|
|
|
+ # The next start goes out on top of the parked timer and parks again.
|
|
|
+ await run(720, True)
|
|
|
+ await run(720, True)
|
|
|
+
|
|
|
+ assert pm.send_drying_command.call_count == AUTO_DRY_MAX_NEVER_HEATED_CYCLES
|
|
|
+ unit = scheduler._auto_dry_units[UNIT]
|
|
|
+ assert unit["suspended"] is True
|
|
|
+ notify.on_ams_drying_suspended.assert_awaited_once()
|
|
|
+ assert notify.on_ams_drying_suspended.await_args.kwargs["never_heated"] is True
|
|
|
+
|
|
|
+ _age_out_cooldown(scheduler)
|
|
|
+ await run(720, True)
|
|
|
+ assert pm.send_drying_command.call_count == AUTO_DRY_MAX_NEVER_HEATED_CYCLES
|
|
|
+
|
|
|
+ @pytest.mark.asyncio
|
|
|
+ async def test_a_cycle_that_runs_resets_the_parked_count(self, env):
|
|
|
+ scheduler, pm, notify, run = env
|
|
|
+ await _parked_cycle(run)
|
|
|
+ _age_out_cooldown(scheduler)
|
|
|
+ # This one counts down and finishes.
|
|
|
+ await run(720, True)
|
|
|
+ await run(719, False)
|
|
|
+ await run(0, False)
|
|
|
+
|
|
|
+ assert "never_heated" not in scheduler._auto_dry_units[UNIT]
|
|
|
+ notify.on_ams_drying_suspended.assert_not_awaited()
|
|
|
+
|
|
|
+ @pytest.mark.asyncio
|
|
|
+ async def test_dry_humidity_lifts_a_not_heating_suspension(self, env):
|
|
|
+ scheduler, _pm, _notify, run = env
|
|
|
+ scheduler._auto_dry_units[UNIT] = {"suspended": True, "never_heated": 2, "ended_at": None}
|
|
|
+ await run(0, False, humidity=DRY)
|
|
|
+ unit = scheduler._auto_dry_units[UNIT]
|
|
|
+ assert not unit.get("suspended")
|
|
|
+ assert "never_heated" not in unit
|
|
|
+
|
|
|
+
|
|
|
+class TestSyncDryingState:
|
|
|
+ def test_a_printer_with_only_a_parked_timer_is_not_drying(self):
|
|
|
+ scheduler = PrintScheduler()
|
|
|
+ scheduler._drying_in_progress[1] = time.monotonic()
|
|
|
+ with patch("backend.app.services.print_scheduler.printer_manager") as pm:
|
|
|
+ pm.get_status.return_value = _state(720, True)
|
|
|
+ scheduler._sync_drying_state()
|
|
|
+ assert 1 not in scheduler._drying_in_progress
|
|
|
+
|
|
|
+ def test_a_running_timer_keeps_the_printer_drying(self):
|
|
|
+ scheduler = PrintScheduler()
|
|
|
+ scheduler._drying_in_progress[1] = time.monotonic()
|
|
|
+ with patch("backend.app.services.print_scheduler.printer_manager") as pm:
|
|
|
+ pm.get_status.return_value = _state(700, False)
|
|
|
+ scheduler._sync_drying_state()
|
|
|
+ assert 1 in scheduler._drying_in_progress
|
|
|
+
|
|
|
+
|
|
|
+class TestNotification:
|
|
|
+ @pytest.mark.asyncio
|
|
|
+ @pytest.mark.parametrize(
|
|
|
+ ("never_heated", "template"),
|
|
|
+ [(False, "ams_drying_suspended"), (True, "ams_drying_not_heating")],
|
|
|
+ )
|
|
|
+ async def test_picks_the_template_on_the_same_switch(self, never_heated, template):
|
|
|
+ from backend.app.services.notification_service import NotificationService
|
|
|
+
|
|
|
+ service = NotificationService()
|
|
|
+ with (
|
|
|
+ patch.object(service, "_get_providers_for_event", new_callable=AsyncMock) as get,
|
|
|
+ patch.object(service, "_send_to_providers", new_callable=AsyncMock),
|
|
|
+ patch.object(service, "_build_message_from_template", new_callable=AsyncMock) as build,
|
|
|
+ ):
|
|
|
+ get.return_value = [MagicMock()]
|
|
|
+ build.return_value = ("t", "m")
|
|
|
+ await service.on_ams_drying_suspended(
|
|
|
+ 1, "P2S", "HT-A", 75.0, 60.0, 2, AsyncMock(), never_heated=never_heated
|
|
|
+ )
|
|
|
+ assert get.await_args.args[1] == "on_ams_drying_suspended"
|
|
|
+ assert build.await_args.args[1] == template
|