@@ -25,6 +25,7 @@ All notable changes to Bambuddy will be documented in this file.
|
|
|
|
|
|
### Fixed
|
|
|
- **Local Profiles Not Shown in AMS Slot Configuration** — Imported local filament profiles were hidden in the AMS slot configure modal when a printer model was set. The `compatible_printers` filter parsed the stored JSON array as a semicolon-delimited string, so the matching always failed and every local preset was silently skipped. Removed the filter entirely — user-imported profiles should be available on any printer.
|
|
|
+- **Interface Aliases Not Shown in Virtual Printer Interface Select** — Interface aliases (e.g. `eth0:1`) added for multi-virtual-printer setups were invisible in the bind IP dropdown. The Docker image didn't include `iproute2`, so the `ip` command wasn't available and the code fell back to ioctl-based enumeration which can only return one IP per interface. Added `iproute2` to the Docker image.
|
|
|
- **Debug Logging Endpoint 500 Error** — The `GET /api/v1/support/debug-logging` endpoint returned a 500 Internal Server Error when the database contained a timezone-aware timestamp written by a previous version. The duration calculation subtracted a timezone-aware datetime from a naive `datetime.now()`, raising `TypeError`. Now strips timezone info when reading the stored timestamp.
|
|
|
- **Bed Cooled Notification Never Fires** ([#497](https://github.com/maziggy/bambuddy/issues/497)) — The bed cooldown monitor always timed out after 30 minutes without sending a notification. After print completion, P1S (and likely other models) sends partial MQTT status updates that don't include `bed_temper`, so the cached bed temperature stayed frozen at the end-of-print value and never dropped below the threshold. The monitor now sends periodic `pushall` commands to the printer to force fresh temperature data. Also added debug logging to the polling loop for future diagnostics.
|
|
|
- **Notification Provider Missing Event Toggles on Create** ([#497](https://github.com/maziggy/bambuddy/issues/497)) — When creating a new notification provider, the `on_bed_cooled` toggle and all 7 queue event toggles (`on_queue_job_added`, `on_queue_job_assigned`, `on_queue_job_started`, `on_queue_job_waiting`, `on_queue_job_skipped`, `on_queue_job_failed`, `on_queue_completed`) were silently discarded. The create endpoint manually listed each field but omitted these 8 toggles, so they always defaulted to `false` regardless of user selection. Editing an existing provider worked correctly.
|