@@ -2,21 +2,41 @@
|
|
|
|
|
|
H2-series trays carry no ``k`` field of their own — only ``cali_idx`` — so the
|
|
|
K value on the AMS slot card (#2854) is looked up from the printer's
|
|
|
-calibration table in ``state.kprofiles``. That table is not flat: the printer
|
|
|
-numbers it **per nozzle**, so entry 16 exists under every nozzle it holds
|
|
|
-profiles for and means a different profile on each.
|
|
|
+calibration table in ``state.kprofiles``.
|
|
|
|
|
|
-``state.kprofiles`` is the union across nozzle diameters (see
|
|
|
-``BambuMQTTClient._store_kprofiles``), which is what the assign paths need but
|
|
|
-makes ``cali_idx`` alone ambiguous. Resolution here is therefore:
|
|
|
+That table is not a clean per-nozzle numbering, and treating it as one is what
|
|
|
+blanked every slot on a second AMS (#3044). Both of these happen:
|
|
|
|
|
|
-1. the slot's own extruder, which separates the two nozzles of a dual-nozzle
|
|
|
- machine outright;
|
|
|
-2. failing that, the diameters currently installed, which separates a live
|
|
|
- table from one left behind by a nozzle that has since been swapped out.
|
|
|
+* Two profiles can share a ``cali_idx`` and differ by extruder — measured on
|
|
|
+ the maintainer's H2C, where one spool read 0.018 on the left nozzle and
|
|
|
+ 0.020 on the right. Resolving on ``cali_idx`` alone showed the wrong one.
|
|
|
+* One profile can be what *both* extruders' slots point at. In the #3044
|
|
|
+ capture an X2D's B1 and B3 carried exactly the K values of A4 and A1 — the
|
|
|
+ same entries, tagged with one extruder. Demanding an extruder match left
|
|
|
+ every slot on the right-hand AMS blank.
|
|
|
|
|
|
-If both fail to single out one profile the answer is ``None``. A blank space on
|
|
|
-the card is a smaller error than confidently printing the other nozzle's number.
|
|
|
+The two are told apart by whether the table distinguishes extruders *at all*:
|
|
|
+
|
|
|
+1. a profile filed under the slot's own extruder wins outright;
|
|
|
+2. if the slot's extruder appears nowhere in the table, its tagging carries no
|
|
|
+ information about this slot, so match on ``cali_idx`` alone — taking the
|
|
|
+ answer only when the candidates agree on one K value, with the diameters
|
|
|
+ currently installed as the tie-break (which separates a live table from one
|
|
|
+ left behind by a nozzle that has since been swapped out).
|
|
|
+
|
|
|
+The condition on step 2 is what keeps the H2C case fixed. There extruder 0 does
|
|
|
+hold profiles, so a right-hand slot pointing at an index only the left hotend
|
|
|
+has is a real miss — the index means entry 16 *of the right nozzle's table*,
|
|
|
+and the left's entry 16 is a different profile. Falling back there is how the
|
|
|
+wrong K got shown in the first place.
|
|
|
+
|
|
|
+BambuStudio is looser still: ``AMSItem.cpp`` fills the same card through
|
|
|
+``CalibUtils::get_pa_k_n_value_by_cali_idx``, which scans the whole history for
|
|
|
+a matching ``cali_idx`` and takes the first hit regardless of nozzle.
|
|
|
+
|
|
|
+If neither step singles out one value the answer is ``None``. A blank space on
|
|
|
+the card is a smaller error than confidently printing the other nozzle's
|
|
|
+number.
|
|
|
"""
|
|
|
|
|
|
from collections.abc import Callable
|
|
|
@@ -34,6 +54,9 @@ def build_slot_k_resolver(state) -> Callable[[int | None, int, int], float | Non
|
|
|
# detects the ambiguity: more than one entry means two nozzles' tables both
|
|
|
# claim this index on this extruder.
|
|
|
table: dict[tuple[int, int], dict[str, float]] = {}
|
|
|
+ # cali_idx -> [(nozzle_diameter, k)], every extruder together. The fallback
|
|
|
+ # for an index no profile claims on the slot's own extruder.
|
|
|
+ shared: dict[int, list[tuple[str, float]]] = {}
|
|
|
for kp in getattr(state, "kprofiles", None) or []:
|
|
|
if kp.slot_id is None or not kp.k_value:
|
|
|
continue
|
|
|
@@ -45,22 +68,45 @@ def build_slot_k_resolver(state) -> Callable[[int | None, int, int], float | Non
|
|
|
extruder = int(kp.extruder_id or 0)
|
|
|
except (ValueError, TypeError):
|
|
|
extruder = 0
|
|
|
- table.setdefault((extruder, kp.slot_id), {})[str(kp.nozzle_diameter or "")] = k_value
|
|
|
+ nozzle = str(kp.nozzle_diameter or "")
|
|
|
+ table.setdefault((extruder, kp.slot_id), {})[nozzle] = k_value
|
|
|
+ shared.setdefault(kp.slot_id, []).append((nozzle, k_value))
|
|
|
+
|
|
|
+ # Which extruders the table names at all. An extruder missing from this is
|
|
|
+ # one the printer is not filing profiles under, which is what makes the
|
|
|
+ # cali_idx-only fallback safe for it.
|
|
|
+ extruders_filed = {extruder for extruder, _ in table}
|
|
|
|
|
|
installed = {str(n.nozzle_diameter) for n in (getattr(state, "nozzles", None) or []) if n.nozzle_diameter}
|
|
|
|
|
|
+ def _agreed(candidates: list[tuple[str, float]]) -> float | None:
|
|
|
+ """The one K these candidates describe, or None if they disagree.
|
|
|
+
|
|
|
+ Values rather than entries: two nozzles listing the same number is not
|
|
|
+ an ambiguity, it is the shared profile the fallback exists for.
|
|
|
+ """
|
|
|
+ values = {k for _, k in candidates}
|
|
|
+ if len(values) == 1:
|
|
|
+ return values.pop()
|
|
|
+ live = {k for nozzle, k in candidates if nozzle in installed}
|
|
|
+ return live.pop() if len(live) == 1 else None
|
|
|
+
|
|
|
def resolve(cali_idx: int | None, ams_id: int, tray_id: int) -> float | None:
|
|
|
if cali_idx is None:
|
|
|
return None
|
|
|
extruder = slot_extruder(ams_id, tray_id, state.ams_extruder_map, state.ams_switch_inlet)
|
|
|
# Single-nozzle printers report everything under extruder 0, and that
|
|
|
# is also the right default when the routing is simply unknown.
|
|
|
- by_nozzle = table.get((extruder if extruder is not None else 0, cali_idx))
|
|
|
- if not by_nozzle:
|
|
|
+ own = extruder if extruder is not None else 0
|
|
|
+ by_nozzle = table.get((own, cali_idx))
|
|
|
+ if by_nozzle:
|
|
|
+ if len(by_nozzle) == 1:
|
|
|
+ return next(iter(by_nozzle.values()))
|
|
|
+ live = [k for nozzle, k in by_nozzle.items() if nozzle in installed]
|
|
|
+ return live[0] if len(live) == 1 else None
|
|
|
+ if own in extruders_filed:
|
|
|
return None
|
|
|
- if len(by_nozzle) == 1:
|
|
|
- return next(iter(by_nozzle.values()))
|
|
|
- live = [k for nozzle, k in by_nozzle.items() if nozzle in installed]
|
|
|
- return live[0] if len(live) == 1 else None
|
|
|
+ candidates = shared.get(cali_idx)
|
|
|
+ return _agreed(candidates) if candidates else None
|
|
|
|
|
|
return resolve
|