MX 0bf9767883 API 31 / unzip sources %!s(int64=2) %!d(string=hai) anos
..
media 0bf9767883 API 31 / unzip sources %!s(int64=2) %!d(string=hai) anos
README.md 0bf9767883 API 31 / unzip sources %!s(int64=2) %!d(string=hai) anos
application.fam 0bf9767883 API 31 / unzip sources %!s(int64=2) %!d(string=hai) anos
co2_icon_10x10.png 0bf9767883 API 31 / unzip sources %!s(int64=2) %!d(string=hai) anos
mh_z19app.c 0bf9767883 API 31 / unzip sources %!s(int64=2) %!d(string=hai) anos

README.md

flipper-zero-mh-z19

Application for measuring carbon dioxide (CO2) with mh-z19 sensor and Flipper zero

Ok ppm Bad ppm Very bad ppm Setup

Instalation Guide

  • Clone application source code

    git clone https://github.com/meshchaninov/flipper-zero-mh-z19.git
    
  • Clone flipper zero source code

    git clone --recursive https://github.com/flipperdevices/flipperzero-firmware.git
    
  • Move mh_z19 folder to flipperzero-firmware/application_user folder

    mv flipper-zero-mh-z19/mh_z19 flipperzero-firmware/application_user
    
  • Connect flipper zero via USB to your computer

  • Build and flash to device firmware

    cd flipperzero-firmware
    ./fbt
    ./fbt flash_usb
    

How to use

  • Connect MH-Z19 sensor to your flipper zero:

    sensor <-> flipper zero
    5V <-> 5V (1 pin)
    GND <-> GND (8 pin)
    PWM <-> A6 (3 pin)
    

    setup

  • Open in flipper zero: Applications -> GPIO -> [MH-Z19] CO2 sensor